This is an HTML version of an attachment to the Freedom of Information request 'Asbestos report for Shiremoor metro station'.





Lucion Services Ltd
Registered in England + Wales 9476425
VAT Registration Number 208156326
Site Asbestos Compendium Summary
This compendium report is based on Site id: 171167, Client Site Ref: Shiremoor Station, Client Ref: Shiremoor
Station, Account Ref No: 3074
Shiremoor Station, Nexus Metro Station Park Lane, Shiremoor,
North Tyneside, NE27 0NT
This Site Asbestos Compendium Summary report has been produced at the request of Tyne and Wear Metro T/a Nexus
it is a summary of asbestos survey findings. Not all of this buildings or items within may have been surveyed for asbestos
containing materials - check for exceptions below. Information in this report should not be regarded as an exhaustive
inventory of all asbestos containing materials on these premises. Any proposed work of an intrusive nature in the vicinity of
asbestos containing material as identified in this summary MUST in the first instance be referred to Tyne and Wear Metro
T/a Nexus building and civil section.
This Compendium Asbestos report aims to be concise, yet comprehensive compilation of asbestos records relating
to Shiremoor Station, Nexus Metro Station Park Lane, Shiremoor, North Tyneside, NE27 0NT. This compendium will
summarize larger work shown in individual reports undertaken for jobs carried out on this site.
The full Site Asbestos Compendium report can be found at:
https://web.lucion.co.uk/print/compendium/171167?s=cfcd2b6fd017aba94cb5fabc3b3e7227
Cover Photo
Most Recent Site Photo
Overview of Jobs carried out at this Site
Job ID
Job-Type
Start Date
Due Date
187929
Survey, Management
355972
Survey, Pre-refurbishment
Thursday, 5th September, 2019
Wednesday, 25th September, 2019
Breakdown of Asbestos findings
Asbestos should be presumed to be present within Locations and Items not accessed until further assessment.
Additional surveyor comments.
Head Office
E:

Issuing Office:
T:













Breakdown of Asbestos findings
↓ Previous Asbestos Records
Most Recent Asbestos Records ↓
Building: Shiremoor Metro Station
Level: 0
Location: 001/Station platform
Fibre-
First Record
Item
Material
Score Extent Recommend Latest Record
Type
VE panels
Asbestos Insulating
--
--
--
--
Board
(inspected during Survey, Survey, Management)
PRESUME
Rear panels to platform bus stop
signs
No Asbestos Identified
NAD
--
--
(inspected during Survey, Survey, Management)
NAD
Location: 001/Station Platform - Turning
Building: Shiremoor Metro Station
Level: 0
Chambers
No reportable Items and Materials recorded at this Location
Building: Shiremoor Metro Station
Level: 0
Location: 002/C&S room
First Record
Item
Material
Fibre-Type
Score
Extent
Recommend
Latest Record
Debris within floor duct
No Asbestos Identified
NAD
--
--
(inspected during Survey, Survey, Management)
NAD
Building: Shiremoor Metro Station
Level: 0
Location: 003/Station platform
Fibre-
First Record
Item
Material
Score Extent Recommend Latest Record
Type
VE panels
Asbestos Insulating
--
--
--
--
Board
(inspected during Survey, Survey, Management)
PRESUME
Rear panels to platform bus stop
signs
No Asbestos Identified
NAD
--
--
(inspected during Survey, Survey, Management)
NAD
Location: 003/Station Platform - Turning
Building: Shiremoor Metro Station
Level: 0
Chambers
No reportable Items and Materials recorded at this Location
Location: 001/Platform 1 - Goal Post Advertising
Building: Shiremoor Station
Level: 0
Panel 1
Limited Access: unable to open
Unable to
access panels due to sealed and rounded screws
heads.
https://web.lucion.co.uk/compact_compendium/171167 - rendered on Fri 27 Mar 2020 @ 10:43:27
Page 2 of 4














Breakdown of Asbestos findings
table continued from previous page...
Location: 001/Platform 1 - Goal Post Advertising
Building: Shiremoor Station
Level: 0
Panel 1
First Record
Item
Material
Fibre-Type
Score
Extent
Recommend
Latest Record
rear access panel
composite
NAD
--
1 No.
NAD
lining behind access panels
supalux
NAD
--
3 No.
The top access panel has been removed causing heavy damage to the internal lining. This has led to
debris being present to the goal post sign structure.
NAD
debris to floor being goal post sign
supalux debris
NAD
--
2 Sqm.
The top access panel has been removed causing heavy damage to the internal lining. This has led to
debris being present to the floor off the platform within the vegetation.
NAD
Location: 002/Platform 1 - Goal Post Advertising
Building: Shiremoor Station
Level: 0
Panel 2
Limited Access: unable to open
Unable to
access panels due to sealed and rounded screws
heads.
First Record
Item
Material
Fibre-Type
Score
Extent
Recommend
Latest Record
rear access panel
composite
NAD
--
1 No.
NAD
lining behind access panels
supalux
NAD
--
3 No.
The top access panel has been removed causing heavy damage to the internal lining. This has led to
debris being present to the goal post sign structure.
NAD
debris to floor being goal post sign
supalux debris
NAD
--
2 Sqm.
The top access panel has been removed causing heavy damage to the internal lining. This has led to
debris being present to the floor off the platform within the vegetation.
NAD
Building: Shiremoor Station
Level: 0
Location: 003/Platform 1 Concourse - VE Panel
First Record
Item
Material
Fibre-Type
Score
Extent
Recommend
Latest Record
lining to VE panel
supalux
NAD
--
4 No.
NAD
https://web.lucion.co.uk/compact_compendium/171167 - rendered on Fri 27 Mar 2020 @ 10:43:27
Page 3 of 4















Breakdown of Asbestos findings
Building: Shiremoor Station
Level: 0
Location: 004/Platform 1 Stairwell - VE Panel
First Record
Item
Material
Fibre-Type
Score
Extent
Recommend
Latest Record
lining to VE panel
supalux
NAD
--
1 No.
NAD
Building: Shiremoor Station
Level: 0
Location: 005/Platform 2 Concourse - VE Panel
Fibre-
First Record
Item
Material
Score Extent Recommend Latest Record
Type
lining to VE panel
supalux
NAD
--
4 No.
NAD
debris to floor within recess between ramp and
2
platform
supalux
NAD
--
Sqm.
Debris present from previous removals of supalux panels.
NAD
debris to concrete ledges with recess between ramp
and platform
supalux
NAD
--
--
Debris present from previous removals of supalux panels.
NAD
Location: 006/Platform 2 - Goal Post Advertising
Building: Shiremoor Station
Level: 0
Panel 1
Limited Access: unable to open
Unable to
access panels due to sealed and rounded screws
heads.
First Record
Item
Material
Fibre-Type
Score
Extent
Recommend
Latest Record
lining behind access panels
supalux
NAD
--
3 No.
Unable to access without causing significant damage. Lining must be presumed within.
NAD
Location: 007/Platform 2 - Goal Post Advertising
Building: Shiremoor Station
Level: 0
Panel 2
Limited Access: unable to open
Unable to
access panels due to sealed and rounded screws
heads.
First Record
Item
Material
Fibre-Type
Score
Extent
Recommend
Latest Record
lining behind access panels
supalux
NAD
--
3 No.
Unable to access without causing significant damage. Lining must be presumed within.
NAD
https://web.lucion.co.uk/compact_compendium/171167 - rendered on Fri 27 Mar 2020 @ 10:43:27
Page 4 of 4