This is an HTML version of an attachment to the Freedom of Information request 'TfB and CDC Planning Application PL/18/4107/FA'.

6
HEALTH, SAFETY & ENVIRONMENT
It is the responsibility of the client to ensure that those undertaking
the works are competent and experienced in the type of work to be
7
10.32
undertaken.
In addition to the hazards usually associated with the types of work
8
detailed on this drawing, the following specific hazards have been
identified through design risk assessment.  The planning and
execution of the works should take into account all usual and specific
hazards.
1.00
1.665
3.915
1.385
Hazards should also be taken into account in the maintenance,
operation, decommissioning and demolition of the works.
Phoenix 2 Duo Kitchen & Food Waste Recycler (P2-12W with Elite 6x4 chassis)
9
Overall Length
10.320m
To be confirmed at design stage
Overall Width
2.530m
Overall Body Height
3.756m
Min Body Ground Clearance
0.309m
10
Track Width
2.530m
Lock to lock time
4.00s
Kerb to Kerb Turning Radius
9.450m
NOTES
11
1.
All dimensions are in millimetres (mm) and levels in metres
Above Ordnance Datum (mAOD) unless noted otherwise.
4.312
0.007
2.
Do not scale from this drawing.
3.
The copyright in this drawing belongs to Structa LLP; the
designs and details may not be used on any project other than
12
6.00
0.906
2.503
that indicated in the titleblock.
Medium Sized Car
4.
Where CAD or BIM files of the drawing are issued, they are
Overall Length
4.319m
provided for the convenience of others, and shall not be used
Overall Width
1.686m
for construction purposes or relied upon for accuracy or
Overall Body Height
1.466m
completeness.
Min Body Ground Clearance
0.228m
Max Track Width
1.591m
13
Lock to lock time
4.00s
R0.45
Kerb to Kerb Turning Radius
5.042m
R4.00
14
15
R4.00
16
17
1.20
1.25
V
4
R2.00
R9.00
3
4.30
2
EXISTING ONSITE BUILDINGS REMOVED FROM
P5
01.11.18
SH
DM
MI
SURVEY. DIMENSIONS REVISED. CARPORTS ADDED
P4
29.10.18
UPDATED TO REVISED REFUSE SPECIFICATION
SH
DM
GW
1
AMENDMENTS TO LAYOUT IN ACCORDANCE TO
P3
26.10.18
MT
DM
GW
CLIENTS COMMENTS
AMENDMENTS IN ACCORDANCE TO CLIENTS
P2
25.10.18
MT
DM
GW
COMMENTS
P1
24.10.18
FIRST ISSUE
MT
DM
GW
Rev.
Date
Description
Drawn
Checked Approved
4.10
PLANNING
274 CHARTRIDGE LANE, CHESHAM
REFUSE VEHICLE SITE AUTOTRACK
SHEET 1 OF 4 - INGRESS WITH CAR WAITING
■ Structural
■ Civil
■ Geo-environmental
London  |  Glasgow  |
Hemel Hempstead  |
Swindon  |
Warwick  |
www.structa.co.uk
0m
2
4
6
8
10
Drawing No:
Revision:
SCALE  1 : 100 @ A1
5007-1001
P5
S07.2.2.2.1 Revision 1.0 - 30.03.15

Document Outline